Sensorwell

AWM3201CR

AWM3000 Series airflow sensor, amplified, flow/pressure range: 0 mbar to 1.25 mbar [0 H20 to 0.5 H2O]; straight port style; current output
Like the AWM2000 Series, the dual Wheatstone bridges control airflow measurement.
The AWM3000 Series is amplified; therefore, it can be used to increase the gain and to introduce voltage offsets to the sensor output.
The heater control circuit and the sensing bridge supply circuit are on board the package.

CAUTION
PRODUCT DAMAGE
AWM Series Microbridge Mass Airflow Sensors are not designed to sense liquid flow and
will be damaged by liquid flow through the sensor.
Failure to comply with these instructions could result in product damage.

Jetzt anfragen!

AWM3201CR

Produkt Merkmale

Kenndaten

  • Laser trimmed for improved sensor interchangeability
  • Flow sensing up to 1.0 SLPM
  • Low differential pressure sensing

Anwendungsbereiche

  • Damper control for heating, ventilation, and air conditioning systems
  • Gas analyzers
  • Low vacuum control
  • Process control
  • Medical respirators and ventilators
  • Oxygen concentrators
  • Leak detection equipment
  • Vent hoods
  • Anesthesia control
  • Gas metering
  • Gas chromatography

Technische Daten

Series Name
AWM3000
Signal Conditioning
Amplified
Flow/Pressure Range
0 mbar to 1.25 mbar [0 H20 to 0.5 H2O]
Output Voltage at Trim Point
20.0 mA dc ±1 mA dc
Null Shift over Temperature
±2.0 mA dc max.
Output Shift over Temperature
±32 % Reading
Repeatability
±0.50 % Reading
Null Offset
4 mA dc ±0.4 mA dc
Response Time
60 ms max.
Supply Voltage
10.0 Vdc ±0.01 Vdc
Port Style
Straight
Common Mode Pressure
25 psi
Power Consumption
50 mW typ.
Operating Temperature
-25°C to 85°C [-13°F to 185°F]
Compensated Temperature
-25°C to 85°C [-13°F to 185°F]
Storage Temperature
-40°C to 90°C [-40°F to 194°F]
Media Compatibility
Dry gas only
Weight
10.8 g
Shock
100 g peak (5 drops, 6 axes)
Availability
Global
Comment
A 5 micron filter must be used on differential pressure sensors. Temperature shifts when sensing differential pressure correlates to the density change of the gas over temperature. Output load connected from Vout to GND (current sinking).
UNSPSC Code
41111931
UNSPSC Commodity
41111931 Flow Sensors

Wir sind gerne für Sie da!

Jetzt kontaktieren

Unsere Partner

Kalsdorfer Straße 26 a
8073 Feldkirchen bei Graz
Österreich