AWM5104VN

AWM5000 Series airflow sensor, amplified, flow/pressure range: 0 SLPM to 20.0 SLPM; threaded port style, ¼ NPT
In-Line Flow Measurement
AWM5000 Series Microbridge Mass Airflow Sensors feature a Venturi type flow housing.
They measure flow as high as 20 standard liters per minute (SLPM) while inducing a maximum pressure drop of 2.25″ H2O.
The microbridge chip is in direct contact with the flow stream, greatly reducing error possibilities due to orifice or bypass channel clogging.

Rugged, Versatile Package
The rugged plastic package has been designed to withstand common mode pressures up to 50 psi, and the small sensing element allows 100 g of shock without compromising performance.
The included „AMP“ compatible connector provides reliable connection in demanding applications.

On-board Signal Conditioning
Each AWM5000 sensor contains circuitry which performs amplification, linearization, temperature compensation, and gas calibration.
A 1 to 5 Vdc linear output is possible for all listings regardless of flow range (5, 10, 15, or 20 SLPM) or calibration gas (nitrogen, carbon dioxide, nitrous oxide, or argon).
All calibration is performed by active laser

CAUTION
PRODUCT DAMAGE
AWM Series Microbridge Mass Airflow Sensors are not designed to sense liquid flow and
will be damaged by liquid flow through the sensor.
Failure to comply with these instructions could result in product damage.

Jetzt anfragen!

AWM5104VN

Produkt Merkmale

Kenndaten

  • Linear voltage output
  • Venturi design
  • Remote mounting capability
  • Active laser trimming improves interchangeability
  • Separate gas calibration types:
    -Ar (argon)
    -N2 (nitrogen) or
    -CO2 (carbon dioxide)

Anwendungsbereiche

  • Damper control for heating, ventilation, and air conditioning systems
  • Gas analyzers
  • Low vacuum control
  • Process control
  • Medical respirators and ventilators
  • Oxygen concentrators
  • Leak detection equipment
  • Vent hoods
  • Anesthesia control
  • Gas metering
  • Gas chromatography

Technische Daten

Series Name
AWM5000
Signal Conditioning
Amplified
Flow/Pressure Range
0 SLPM to 20.0 SLPM
Output Voltage at Trim Point
5.0 Vdc at 20 SLPM
Null Shift over Temperature
±0.050 Vdc typ., ±0.20 Vdc max.
Output Shift over Temperature
±7 % Reading
Repeatability
±0.50 % Reading
Null Offset
0.95 Vdc min., 1 Vdc typ., 1.05 Vdc max.
Response Time
60 ms max.
Supply Voltage
8.0 Vdc min., 10.0 Vdc typ., 15.0 Vdc max.
Port Style
1/4 in - 18 NPT
Common Mode Pressure
50 psi
Power Consumption
100 mW max.
Operating Temperature
-20°C to 70°C [-4°F to 158°F]
Compensated Temperature
0°C to 50°C [32°F to 122°F]
Storage Temperature
-20°C to 70°C [-4°F to 158°F]
Media Compatibility
Dry gas only
Weight
60 g
Shock
100 g peak 6 ms half-sine (3 drops, each direction of 3 axes)
Availability
Global
Comment
Nitrogen calibration gas. This calibration is identical to using oxygen or air as calibration gas.
UNSPSC Code
41111931
UNSPSC Commodity
41111931 Flow Sensors